Get-AuvikSNMPPollerSetting
SYNOPSIS
Provides details about one or more SNMP Poller Settings.
SYNTAX
indexByMultiSNMPGeneral (Default)
Get-AuvikSNMPPollerSetting -tenants <String[]> [-filter_deviceId <String>] [-filter_useAs <String>]
[-filter_deviceType <String>] [-filter_makeModel <String>] [-filter_vendorName <String>]
[-filter_oid <String>] [-filter_name <String>] [-page_first <Int64>] [-page_after <String>]
[-page_last <Int64>] [-page_before <String>] [-allPages] [<CommonParameters>]
indexBySingleSNMPGeneral
Get-AuvikSNMPPollerSetting -snmpPollerSettingId <String> [<CommonParameters>]
DESCRIPTION
The Get-AuvikSNMPPollerSetting cmdlet provides details about one or more SNMP Poller Settings.
EXAMPLES
EXAMPLE 1
Get-AuvikSNMPPollerSetting -tenants 123456789
Provides details about the first 100 SNMP Poller Settings associated to the defined tenant
EXAMPLE 2
Get-AuvikSNMPPollerSetting -tenants 123456789 -page_first 1000 -allPages
Provides details about all the SNMP Poller Settings associated to the defined tenant
PARAMETERS
-snmpPollerSettingId
ID of the SNMP Poller Setting to retrieve
Type: String
Parameter Sets: indexBySingleSNMPGeneral
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: True (ByValue)
Accept wildcard characters: False
-tenants
Comma delimited list of tenant IDs to request info from
Type: String[]
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_deviceId
Filter by device ID
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_useAs
Filter by oid type
Allowed values: “serialNo”, “poller”
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_deviceType
Filter by device type
Allowed values: “unknown”, “switch”, “l3Switch”, “router”, “accessPoint”, “firewall”, “workstation”, “server”, “storage”, “printer”, “copier”, “hypervisor”, “multimedia”, “phone”, “tablet”, “handheld”, “virtualAppliance”, “bridge”, “controller”, “hub”, “modem”, “ups”, “module”, “loadBalancer”, “camera”, “telecommunications”, “packetProcessor”, “chassis”, “airConditioner”, “virtualMachine”, “pdu”, “ipPhone”, “backhaul”, “internetOfThings”, “voipSwitch”, “stack”, “backupDevice”, “timeClock”, “lightingDevice”, “audioVisual”, “securityAppliance”, “utm”, “alarm”, “buildingManagement”, “ipmi”, “thinAccessPoint”, “thinClient”
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_makeModel
Filter by the device’s make and model
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_vendorName
Filter by the device’s vendor/manufacturer
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_oid
Filter by OID
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-filter_name
Filter by the name of the SNMP poller setting
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-page_first
For paginated responses, the first N elements will be returned Used in combination with page[after]
Default Value: 100
Type: Int64
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-page_after
Cursor after which elements will be returned as a page The page size is provided by page[first]
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-page_last
For paginated responses, the last N services will be returned Used in combination with page[before]
Default Value: 100
Type: Int64
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False
-page_before
Cursor before which elements will be returned as a page The page size is provided by page[last]
Type: String
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False
-allPages
Returns all items from an endpoint
Highly recommended to only use with filters to reduce API errors\timeouts
Type: SwitchParameter
Parameter Sets: indexByMultiSNMPGeneral
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False
CommonParameters
This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
INPUTS
OUTPUTS
NOTES
N\A
RELATED LINKS
https://celerium.github.io/Auvik-PowerShellWrapper/site/pollers/Get-AuvikSNMPPollerSetting.html